This LG air conditioning condenser suffered from a split condenser coil which resulted in the system losing all its refrigerant gas.
By removing the condenser from the wall mounted brackets we made the job a lot easier to access all the parts that needed to be removed.
Once the condenser coil is removed we start the build up of the new condenser coil which comes in 4 separate parts.
Once built, the coil can be brazed into position and pressure tested before we hang it back onto its brackets.